BFLTC - SCOTH-SEAL(TM) EC-801 B/A (PT A) SEALANT

Product Identification

Product ID:SCOTH-SEAL(TM) EC-801 B/A (PT A) SEALANT
MSDS Date:05/24/1989
FSC:8030
NIIN:00-687-8246
Kit Part:Y
MSDS Number: BFLTC

Responsible Party
3M COMPANY, ADHESIVE COATING & SEALANT DIV.
3M CENTER
ST. PAUL, MN 55144-1000
US

Emergency Phone: 612-733-1110

Info Phone: 612-733-1110

Cage: 04963

Contractor
MINNESOTA MINING AND MFG CO, DBA 3M
SAINT PAUL, MN 55144-1000 US

Telephone: 866-556 5712 / 612-733-1110

Cage: 76381

Ingredients

LEAD PEROXIDE (LEAD DIOXIDE), (OSHA PEL FROM 29CFR

CAS: 1309-60-0

RTECS: OG0700000

Fraction By Weight: 60-70%

OSHA PEL 0.05 MG/M3 (PB)

ACGIH TLV: 0.15 MG/M3(PB); 8990


HYDROGENATED TERPHENYLS

CAS: 61788-32-7

RTECS: WZ6535000

Fraction By Weight: 20-30%

OSHA PEL 0.5 PPM

ACGIH TLV: 0.5 PPM; 9192


LITHARGE

CAS: 1317-36-8

RTECS: OG1750000

Fraction By Weight: 1-10%


LAURIC ACID

CAS: 143-07-7

RTECS: OE9800000

Fraction By Weight: 1-10%


XYLENES (O-,M-,P- ISOMERS) (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 0.1-2.0%

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


SODIUM STEARATE

CAS: 822-20-7

Fraction By Weight: 1.0-2.0%


HYDROXYTITANIUM STEARATE

Fraction By Weight: 1-10%

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE-EYES/SKIN:IRRITATION.
INHALATION:IRRITATION TO THE RESPIRATORY TRACT. INGESTION:LARGE
QUANTITIES CAN CAUSE INTESTINAL DISORDERS. CHRONIC-CNS, HEART,
KIDNEY, LIVER AND BLOOD DAMAGE.
Explanation of Carcinogenicity:THIS TYPE OF LEAD COMPOUND IS NOT LISTED
AS A CARCINOGEN.
Effects of Overexposure:IRRITATION, COUGHING, FATIGUE, LOSS OF
APPETITE, METALLIC TASTE IN MOUTH
Medical Cond Aggravated by Exposure:HEART, LIVER, KIDNEY, AND BLOOD
DISEASES.

First Aid

First Aid:FIRDT AID- INHALATION:REMOVE TO FRESH AIR AND PROVIDE CPR.
EYE CONTACT:FLUSH WITH WATER FOR 15 MINUTES. SKIN CONTACT:WASH WITH
SOAP AND WATER. GET MED ATTENTION IF SYMPTOMS PERSIST. INGESTION:
GET MED ICAL HELP OR CALL POISON CENTER.

Fire Fighting

Extinguishing Media:CO*2, FOAM, DRY CHEMICAL
Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR SELF-CONTAINED
BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:CONTACT WITH REDUCING AGENTS WILL CAUSE
EXLOSION.

Accidental Release

Spill Release Procedures:COLLECT SPILLED MATERIAL USING ABSORBENT
MATERIAL. CLEAN UP RESIDUE & AREA.

Handling

Handling and Storage Precautions:AVOID EYE CONTACT AND PROLONGED SKIN
CONTACT. WASH HANDS BEFORE EATING OR SMOKING. LAUNDER CONTAMINATED
CLOTHING BEFORE REUSE.

Exposure Controls

Respiratory Protection:USE ORGANIC FILTER RESPIRATOR.
Ventilation:MECHANICAL VENTILATION ADEQUATE
Protective Gloves:IMPERV. GLOVES
Eye Protection:SAFETY GLASSES
Other Protective Equipment:EYE WASH AND PROTECTIVE CLOTHING.
Work Hygienic Practices:DO EAT, DRINK OR SMOKE IN WORK AREA.
Supplemental Safety and Health
PART A OF A 2-PART SEALANT KIT.

Chemical Properties

HCC:D1
Boiling Pt:B.P. Text:>600F,>316C
Vapor Pres:<2
Spec Gravity:2.88
Solubility in Water:NEGLIGIBLE
Appearance and Odor:DARK BROWN PASTE, SLIGHT ODOR
Percent Volatiles by Volume:2

Stability

Stability Indicator/Materials to Avoid:YES
REDUCING AGENTS.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:CO, CO*2, LEAD AND SMOKE PARTICLES

Disposal

Waste Disposal Methods:DISPOSE OF IN SECURE LANDFILL AT HAZARDOUS WASTE
MANAGEMENT FACILITY. CONSULT APPROPRIATE FEDERAL, STATE & LOCAL
CODES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.